EPDs and Embodied Carbon in Steel Buildings: What Project Buyers Should Request

Environmental Product Declarations (EPDs) are moving from specialist sustainability reports into ordinary construction procurement. Owners, designers and contractors increasingly ask for product-level environmental information when comparing structural materials, preparing whole-building assessments or responding to project carbon requirements.

For steel building buyers, the challenge is not simply obtaining a PDF labelled “EPD.” The document must be relevant to the product, geography, production route and assessment method being used. It must also be interpreted consistently. This guide explains what to request and where comparisons commonly go wrong.

What is an EPD?

An EPD is a standardised declaration of quantified environmental information for a product or product group. Type III environmental declarations are based on life-cycle assessment principles and product category rules. In construction, EPDs are commonly prepared in frameworks aligned with standards such as ISO 14025 and EN 15804, depending on the market and programme.

An EPD normally reports several environmental indicators across defined life-cycle modules. Global warming potential is often the most discussed indicator, but it is not the only one. The declared unit, system boundary, data period, manufacturing route, allocation rules and end-of-life assumptions all affect interpretation.

An EPD is therefore a disclosure document, not a universal “green product” certificate. It provides structured information. The project team still has to decide whether the information is suitable for the intended comparison and assessment.

Why embodied carbon matters in steel projects

Operational energy has traditionally dominated building sustainability discussions. As building efficiency improves and carbon targets become broader, more attention is moving to emissions associated with material production, fabrication, transport, construction, maintenance and end of life. These are often discussed as embodied carbon, although exact definitions and boundaries vary.

Steel is used at significant scale in warehouses, workshops, hangars and multi-storey structures. Decisions about structural efficiency, steel grade, production route, fabrication, coatings, transport, adaptability and end-of-life scenarios can all influence environmental results. World Steel Association guidance emphasises life-cycle thinking rather than evaluating only one stage in isolation.

Seven checks before accepting an EPD

1. Product match

Confirm that the declaration covers the actual product being supplied. An industry-average EPD for generic structural sections is different from a manufacturer-specific declaration for a defined production route. Neither is automatically wrong, but the distinction must be clear.

2. Programme and verification

Identify the programme operator, applicable product category rules and verification status. Check the publication and validity dates. An expired declaration may still provide background information, but it may not satisfy current project requirements.

3. Declared or functional unit

Results may be stated per tonne, kilogram, square metre or another unit. Values cannot be compared until they are converted to a consistent basis that reflects the actual project quantity and function.

4. Life-cycle modules

Check which modules are reported. Product-stage modules are not equivalent to a complete cradle-to-grave assessment. Transport, construction, maintenance, replacement, demolition, waste processing, recycling and benefits beyond the system boundary may be reported separately.

5. Geography and energy context

Electricity mix, raw-material sourcing, plant technology and transport assumptions can change results. An EPD from another region may not represent the proposed supply chain.

6. Steel production route and recycled-content assumptions

Blast furnace-basic oxygen furnace and electric arc furnace routes can have different input and emissions profiles. Recycled content and end-of-life recycling are related but distinct concepts. Avoid counting the same circularity benefit twice when combining EPD data in a building assessment.

7. Comparability statement

Two EPDs are not automatically comparable simply because both report a global-warming value. Compare the same product function, declared unit, standard version, product category rules, modules and data quality. Where those conditions differ, document the limitation instead of forcing a ranking.

Information to include in an RFQ

If environmental data matters to the project, add the requirement to the request for quotation. A clear request may include:

  • The products and quantities for which EPD data is required.
  • Whether industry-average or manufacturer-specific declarations are acceptable.
  • The required standard, programme or assessment framework.
  • Required life-cycle modules and indicators.
  • Geographic and production-route relevance.
  • Publication, expiry and third-party verification information.
  • Evidence connecting the declaration to the supplied material.
  • Transport distances and modes to the project or port.
  • The format and deadline for data delivery.

This information helps suppliers respond consistently and allows the project team to identify gaps before contract award.

EPD data is only one part of design

A lower value per tonne does not necessarily produce the lowest-impact building. Structural efficiency, member sizing, spans, loads, service life, maintenance, foundations and adaptability also matter. A design that uses less material while meeting performance requirements may change the result more than selecting between two similar declarations.

That is why environmental information should be coordinated with structural decisions. Steel Span Lab’s custom steel structure process starts with project requirements rather than a fixed standard package. When an EPD or carbon target applies, it should be identified alongside the location, dimensions, intended use, loads and applicable standards.

Common procurement mistakes

  • Requesting “an EPD” without defining the product or assessment need.
  • Comparing only one headline number from declarations with different boundaries.
  • Assuming recycled content alone describes total environmental performance.
  • Ignoring fabrication, coatings, transport and construction-stage information.
  • Using an industry average as if it were verified data for a specific mill.
  • Failing to connect the declared product to the final material list.
  • Treating environmental documentation as a substitute for engineering compliance.

A practical review sequence

  1. Define the decision the data must support.
  2. Set the comparison boundary and project rules.
  3. Collect relevant declarations and supporting product information.
  4. Normalise units and document assumptions.
  5. Coordinate results with structural quantities, fabrication and transport.
  6. Have the assessment reviewed by the project’s sustainability and engineering professionals.

The goal is not to turn procurement teams into life-cycle assessment specialists. It is to ask precise questions early enough that qualified specialists receive usable and traceable data.

Need to include environmental documentation in a steel project brief? Contact Steel Span Lab with the project location, intended use and reporting requirements.


Sources and further reading

This article provides general procurement information. Project-specific life-cycle assessment and compliance decisions should be made by qualified professionals using current requirements.

Leave a Comment